How to Change Your Cascadian Filter (and Know When It's Time)

White Filters

McTavish Jones |

Changing a Cascadian filter is regular maintenance, not a sign that something has gone wrong. For ICS cartridge systems, Cascadian recommends replacing the filter about once a year, even if the water still looks fine. This guide covers how to tell when a change is due, how to find the correct kit, and how to install the new cartridge so the housing seals and water can flow through the media.

When to change your filter

Cascadian's installation guide says a filter for an ICS system generally lasts about a year, and that you should follow that schedule even if you don't notice a change. Water quality and how much water you use can shorten or stretch that interval, which is why Cascadian also suggests keeping a spare kit on hand.

Every ICS system and replacement filter comes with a Filter Monitor: a magnetic card and a timer. Press the bubble on the timer to activate it. When it is activated, a red line appears in the window. Write the install or change date on the card, and treat the monitor as a backup to a 12-month calendar reminder, not a replacement for one.

The installation guide and Cascadian's article on how to tell when to change the filter also list signs that a change may already be due:

  • A year has passed since the system was installed or the filter was last changed.
  • Soap suds on treated water are no longer clearly bigger, or spots are no longer easier to clean, than on untreated water.
  • Taste, odor, or staining has come back.
  • If your system has a sediment or carbon filter and you installed inlet and outlet pressure gauges, the pressure difference has changed by about 3 to 5 psi from when the filter was new.
  • Water pressure fluctuates.
  • Brown or orange stains reappear and are hard to clean.
  • Water tastes metallic.
  • Hard-water effects, such as dull laundry or dull-feeling hair, start to return.

Get the right replacement kit

Start with the label on the wall bracket. It shows both the system part number and the replacement filter part number. In most cases the kit is the system number with a K on the end. An ICS-STP takes an ICS-STPK. If the label is missing or worn, use the replacement filter finder or contact Cascadian.

Use the kit made for your system rather than a generic cartridge. If your label has an older number, see Cascadian's part-number history. If an older system has more housings than the current kit has cartridges, Cascadian's guidance is to leave the extra housing empty.

What to have on hand

  • The correct Cascadian replacement kit.
  • The housing wrench, used only to loosen the sump. For 2nd generation whole-home systems sold from April 2019, that wrench is the AF-WRENCH45.
  • Extra SIL-LUBE if you need it.
  • A bucket or drain path, rags, and, if you will disinfect the housing, diluted household bleach mixed at 1/4 cup of bleach per gallon of water. Read and follow the safety directions on the bleach you use.

Protect the floor and the wall around the system. A housing full of water is heavy and can be slippery.

How to change the cartridge

These steps follow Cascadian's ICS Filter Replacement Guide and the ICS installation guide.

  1. Shut off and bypass. Close the inlet and outlet valves. Open the bypass valve if you have one, so untreated water can still reach the house.
  2. Drain and relieve pressure. Open the bottom drain valve, then open the air vent 2 to 3 turns.
  3. Remove the sump. Once it is empty, put the wrench on the sump with the handle facing you and turn left to loosen. Finish by hand, and support the housing from below.
  4. Remove the old cartridge. Dispose of the used filter. Cascadian says filters are not reusable; do not try to clean and reinstall an old cartridge.
  5. Clean and check the seal. Wash your hands, then wipe the inside of the housing with a clean cloth and the diluted bleach, or spray the cap. Check the O-ring. If it is swollen, misshapen, or flattened, replace it. Coat all surfaces of the O-ring with SIL-LUBE only, never a petroleum lubricant. Do not put thread tape or pipe sealant on the housing-to-cap threads. Close the bottom drain.
  6. Unwrap the new cartridge. Remove all of the protective plastic wrap before the cartridge goes into the housing. If you are replacing two cartridges, unwrap one at a time so you know which one belongs in which housing.
  7. Insert it the right way, then hand-tighten. Seat the bottom hole of the cartridge on the centering post in the housing. Hand-tighten the sump to the cap. Do not use the housing wrench to tighten it. Tightening with the wrench can seize the housing and make the next change difficult.

Cartridge orientation matters. If you are using a PolyCor filter, insert it with the blue cap up. If you are using an ICS-PK or ICS-PHK cartridge, install the gasketed end up. Other cartridges can go either way. On two-filter systems, follow the 1 and 2 stickers so the cartridges are in the correct flow order.

Start the system back up and check for leaks

Close the drain and the bypass. Open the air vent about one complete turn. Open the inlet valve just enough to let water in slowly, so the housing fills and air leaves through the vent. The replacement guide then says to close the inlet, wait for the air vent to stop spitting air, and close the vent, so the O-ring can seal. Fully open the inlet and check for leaks, especially where the cap meets the housing.

Open a treated faucet downstream and let the water run for about five minutes, or until it runs clear. That flushes air and filter fines out of the system. Then activate the Filter Monitor and place it somewhere you will see it, such as the refrigerator or the system bracket.

If the housing leaks where it meets the cap, shut the valves, relieve pressure at the vent, and drain the housing. Check the O-ring for damage and the groove for debris, then reinstall a clean, lubricated O-ring and hand-tighten again. If a leak is at a plumbing fitting on the inlet or outlet, do not keep tightening. Cascadian's installation guide says damage from overtightening those fittings is not covered by warranty. Repair by removing the fitting, cleaning off the old PTFE tape, applying fresh tape, and reassembling. PTFE tape belongs on those pipe threads, not on the housing-to-cap threads.

When you are done, the used cartridge still needs a place to go. See Cascadian's guide to disposing of used filters.

Get the kit, or get a hand

Find your replacement filter if you are ready to order. If you would rather have a professional do the change, start with Cascadian's plumber finder. For questions about your specific system, contact Cascadian.

Leave a comment